new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Dec 10

oMEGACat. VII. Tracing Interstellar and Intracluster Medium of $ω$ Centauri using Sodium Absorptions

We investigate the foreground interstellar medium along the line of sight and intracluster medium of omega Centauri (omega Cen) by measuring the equivalent width of Na I D absorptions from MUSE observations. The large line-of-sight velocity difference between omega Cen and the foreground enables us to separate Na I D absorption contributed from atomic gas in the interstellar and intracluster medium. We find that small-scale substructures in the foreground Na I D distribution correlate with differential reddening derived from photometric methods. Using an empirical Na I D equivalent width-reddening relation, we determine an average reddening of E(B-V)=0.153pm0.003 mag within the half-light radius of omega Cen. However, the Na I D-inferred differential reddening is significantly larger than photometric estimates. This is likely due to scatter in the Na I D-reddening relation. We find no evidence for intracluster atomic gas from spectra of horizontal branch stars, as there is no significant Na I D absorption at omega Cen's systemic velocity. Given this non-detection, we place the strongest upper limit to date on the intracluster atomic gas column density in omega Cen of lesssim2.17 times 10^{18}~cm^{-2}. We also estimate the ionized gas density from pulsar dispersion measure variations, which exceed the atomic gas limit by sim50 times. Nevertheless, the strong correlation between dispersion measure and foreground Na I D suggests that much or all of this ionized gas resides in the foreground. Given ongoing mass loss from bright giant stars, our findings imply that the intracluster gas accumulation timescale is short, and gas removal in the cluster is likely not tied to stripping as omega Cen passes through the Galactic disk.

  • 17 authors
·
Sep 30

SPARSE Data, Rich Results: Few-Shot Semi-Supervised Learning via Class-Conditioned Image Translation

Deep learning has revolutionized medical imaging, but its effectiveness is severely limited by insufficient labeled training data. This paper introduces a novel GAN-based semi-supervised learning framework specifically designed for low labeled-data regimes, evaluated across settings with 5 to 50 labeled samples per class. Our approach integrates three specialized neural networks -- a generator for class-conditioned image translation, a discriminator for authenticity assessment and classification, and a dedicated classifier -- within a three-phase training framework. The method alternates between supervised training on limited labeled data and unsupervised learning that leverages abundant unlabeled images through image-to-image translation rather than generation from noise. We employ ensemble-based pseudo-labeling that combines confidence-weighted predictions from the discriminator and classifier with temporal consistency through exponential moving averaging, enabling reliable label estimation for unlabeled data. Comprehensive evaluation across eleven MedMNIST datasets demonstrates that our approach achieves statistically significant improvements over six state-of-the-art GAN-based semi-supervised methods, with particularly strong performance in the extreme 5-shot setting where the scarcity of labeled data is most challenging. The framework maintains its superiority across all evaluated settings (5, 10, 20, and 50 shots per class). Our approach offers a practical solution for medical imaging applications where annotation costs are prohibitive, enabling robust classification performance even with minimal labeled data. Code is available at https://github.com/GuidoManni/SPARSE.

  • 4 authors
·
Aug 8 2

Text-to-CT Generation via 3D Latent Diffusion Model with Contrastive Vision-Language Pretraining

Objective: While recent advances in text-conditioned generative models have enabled the synthesis of realistic medical images, progress has been largely confined to 2D modalities such as chest X-rays. Extending text-to-image generation to volumetric Computed Tomography (CT) remains a significant challenge, due to its high dimensionality, anatomical complexity, and the absence of robust frameworks that align vision-language data in 3D medical imaging. Methods: We introduce a novel architecture for Text-to-CT generation that combines a latent diffusion model with a 3D contrastive vision-language pretraining scheme. Our approach leverages a dual-encoder CLIP-style model trained on paired CT volumes and radiology reports to establish a shared embedding space, which serves as the conditioning input for generation. CT volumes are compressed into a low-dimensional latent space via a pretrained volumetric VAE, enabling efficient 3D denoising diffusion without requiring external super-resolution stages. Results: We evaluate our method on the CT-RATE dataset and conduct a comprehensive assessment of image fidelity, clinical relevance, and semantic alignment. Our model achieves competitive performance across all tasks, significantly outperforming prior baselines for text-to-CT generation. Moreover, we demonstrate that CT scans synthesized by our framework can effectively augment real data, improving downstream diagnostic performance. Conclusion: Our results show that modality-specific vision-language alignment is a key component for high-quality 3D medical image generation. By integrating contrastive pretraining and volumetric diffusion, our method offers a scalable and controllable solution for synthesizing clinically meaningful CT volumes from text, paving the way for new applications in data augmentation, medical education, and automated clinical simulation.

  • 5 authors
·
May 31

BodySLAM: A Generalized Monocular Visual SLAM Framework for Surgical Applications

Endoscopic surgery relies on two-dimensional views, posing challenges for surgeons in depth perception and instrument manipulation. While Monocular Visual Simultaneous Localization and Mapping (MVSLAM) has emerged as a promising solution, its implementation in endoscopic procedures faces significant challenges due to hardware limitations, such as the use of a monocular camera and the absence of odometry sensors. This study presents BodySLAM, a robust deep learning-based MVSLAM approach that addresses these challenges through three key components: CycleVO, a novel unsupervised monocular pose estimation module; the integration of the state-of-the-art Zoe architecture for monocular depth estimation; and a 3D reconstruction module creating a coherent surgical map. The approach is rigorously evaluated using three publicly available datasets (Hamlyn, EndoSLAM, and SCARED) spanning laparoscopy, gastroscopy, and colonoscopy scenarios, and benchmarked against four state-of-the-art methods. Results demonstrate that CycleVO exhibited competitive performance with the lowest inference time among pose estimation methods, while maintaining robust generalization capabilities, whereas Zoe significantly outperformed existing algorithms for depth estimation in endoscopy. BodySLAM's strong performance across diverse endoscopic scenarios demonstrates its potential as a viable MVSLAM solution for endoscopic applications.

  • 6 authors
·
Aug 6, 2024